{"id":5131,"date":"2026-06-09T08:53:05","date_gmt":"2026-06-09T08:53:05","guid":{"rendered":"https:\/\/materialparts.com\/aq24canfd-02htg\/"},"modified":"2026-06-09T08:53:05","modified_gmt":"2026-06-09T08:53:05","slug":"aq24canfd-02htg","status":"publish","type":"post","link":"https:\/\/materialparts.com\/zh\/aq24canfd-02htg\/","title":{"rendered":"AQ24CANFD-02HTG"},"content":{"rendered":"<h2>\u4ea7\u54c1\u6982\u89c8<\/h2>\n<p>The AQ24CANFD-02HTG from Littelfuse is a 2-channel bidirectional TVS diode array for CAN FD bus protection, featuring \u00b121 kV ESD, AEC-Q101 qualification, and 12 pF capacitance.<\/p>\n<h2>\u4e3b\u8981\u89c4\u683c<\/h2>\n<table>\n<tr>\n<td>\u5236\u9020\u5546<\/td>\n<td>Littelfuse<\/td>\n<\/tr>\n<tr>\n<td>VRWM<\/td>\n<td>24V<\/td>\n<\/tr>\n<tr>\n<td>VBR min<\/td>\n<td>26.7V<\/td>\n<\/tr>\n<tr>\n<td>Clamping Voltage<\/td>\n<td>33V @ 1A<\/td>\n<\/tr>\n<tr>\n<td>ESD (Contact)<\/td>\n<td>\u00b121 kV<\/td>\n<\/tr>\n<tr>\n<td>Surge (8\/20\u00b5s)<\/td>\n<td>3A<\/td>\n<\/tr>\n<tr>\n<td>Leakage<\/td>\n<td>0.02 \u00b5A<\/td>\n<\/tr>\n<tr>\n<td>Capacitance<\/td>\n<td>12 pF typical<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Resistance<\/td>\n<td>0.5 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>\u5305\u88c5<\/td>\n<td>SOT-23-3L<\/td>\n<\/tr>\n<tr>\n<td>\u5de5\u4f5c\u6e29\u5ea6<\/td>\n<td>-55\u00b0C \u81f3 +150\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u8d44\u683c<\/td>\n<td>AEC-Q101<\/td>\n<\/tr>\n<\/table>\n<h2>\u7279\u70b9<\/h2>\n<ul>\n<li>\u00b121 kV IEC 61000-4-2 ESD protection<\/li>\n<li>3A surge (8\/20\u00b5s) capability<\/li>\n<li>Low 12 pF capacitance for CAN FD signals<\/li>\n<li>Bidirectional protection<\/li>\n<li>AEC-Q101 qualified<\/li>\n<li>Low clamping voltage: 33V @ 1A<\/li>\n<li>Low leakage: 0.02 \u00b5A<\/li>\n<li>MSL-1 unlimited<\/li>\n<\/ul>\n<h2>\u5e94\u7528<\/h2>\n<ul>\n<li>CAN\/CAN FD bus protection<\/li>\n<li>Automotive ECU protection<\/li>\n<li>Body control modules<\/li>\n<li>ADAS control units<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Product Overview The AQ24CANFD-02HTG from Littelfuse is a 2-channel bidirectional TVS diode array for CAN FD bus protection, featuring \u00b121 kV ESD, AEC-Q101 qualification, and 12 pF capacitance. Key Specifications Manufacturer Littelfuse VRWM 24V VBR min 26.7V Clamping Voltage 33V @ 1A ESD (Contact) \u00b121 kV Surge (8\/20\u00b5s) 3A Leakage 0.02 \u00b5A Capacitance 12 pF [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13,20],"tags":[],"chip_brand":[200],"class_list":["post-5131","post","type-post","status-publish","format-standard","hentry","category-integrated-circuits-ics","category-interface-ics","chip_brand-littelfuse"],"acf":{"brief_explanation":"CAN FD TVS protector, 24V, \u00b121kV ESD, 12pF, AEC-Q101, SOT-23-3","date_code":"","package_case":"SOT-23-3L (2.9 x 1.3 x 1.0 mm)","in_stock":4103,"datasheet":"https:\/\/www.littelfuse.com\/media\/littelfuse\/datasheets\/littelfuse_tvs_diode_arrays_aq24canfd.pdf","price":"$0.29 @ 1ku","product_introduction":"The AQ24CANFD-02HTG from Littelfuse is a specialized TVS diode array for CAN and CAN FD bus protection. Providing \u00b121 kV ESD per IEC 61000-4-2 and 3A surge capability, it safeguards CAN transceivers from transient threats. The low 12 pF capacitance preserves signal integrity at CAN FD data rates up to 5 Mbps. AEC-Q101 qualified and bidirectional, designed for 12V\/24V automotive CAN systems.","working_principle":"Bidirectional TVS diodes are connected between CAN bus lines and ground. Under normal operation, the TVS presents high impedance with only 0.02 \u00b5A leakage. When a transient exceeds the breakdown voltage (26.7V min), the TVS rapidly clamps to a safe level (33V @ 1A), diverting surge current away from the protected transceiver.","pin_description":"<table><tr><th>Pin<\/th><th>Name<\/th><th>Function<\/th><\/tr><tr><td>1<\/td><td>IO1<\/td><td>Bus line 1 (CANH\/CANL)<\/td><\/tr><tr><td>2<\/td><td>GND<\/td><td>Ground<\/td><\/tr><tr><td>3<\/td><td>IO2<\/td><td>Bus line 2 (CANL\/CANH)<\/td><\/tr><\/table>","application_scenarios":"<ul><li>Automotive CAN FD ECU protection<\/li><li>Body control module CAN interfaces<\/li><li>ADAS control unit bus protection<\/li><li>Powertrain control CAN networks<\/li><\/ul>","alternative_models":"<table><tr><th>Manufacturer<\/th><th>Part Number<\/th><th>Notes<\/th><\/tr><tr><td>NXP<\/td><td>AUML05F1<\/td><td>CAN bus protector<\/td><\/tr><tr><td>onsemi<\/td><td>NUP2105LT1G<\/td><td>CAN\/LIN TVS<\/td><\/tr><tr><td>TI<\/td><td>ESD351<\/td><td>CAN ESD protection<\/td><\/tr><\/table>"},"_links":{"self":[{"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/posts\/5131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/comments?post=5131"}],"version-history":[{"count":0,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/posts\/5131\/revisions"}],"wp:attachment":[{"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/media?parent=5131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/categories?post=5131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/tags?post=5131"},{"taxonomy":"chip_brand","embeddable":true,"href":"https:\/\/materialparts.com\/zh\/wp-json\/wp\/v2\/chip_brand?post=5131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}