{"id":9380,"date":"2026-07-03T06:18:05","date_gmt":"2026-07-03T06:18:05","guid":{"rendered":"https:\/\/materialparts.com\/max30003cwvt\/"},"modified":"2026-07-03T07:37:45","modified_gmt":"2026-07-03T07:37:45","slug":"max30003cwvt","status":"publish","type":"post","link":"https:\/\/materialparts.com\/ar\/max30003cwvt\/","title":{"rendered":"MAX30003CWV+T"},"content":{"rendered":"<h2>\u0646\u0638\u0631\u0629 \u0639\u0627\u0645\u0629 \u0639\u0644\u0649 \u0627\u0644\u0645\u0646\u062a\u062c<\/h2>\n<p>The MAX30003CWV+T is an ultra-low power, single-channel integrated biopotential analog front-end (AFE) from Analog Devices (formerly Maxim Integrated), designed for ECG (electrocardiogram) and R-to-R heart rate detection in wearable applications. It features 15.5-bit effective resolution with 5uVp-p noise, built-in R-R detection algorithm, and operates on just 85uW at 1.1V. The CWV package is a 30-bump wafer-level package (WLP) measuring 2.7 x 2.9mm.<\/p>\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<table>\n<tr>\n<td>\u0627\u0644\u0642\u0646\u0648\u0627\u062a<\/td>\n<td>1 biopotential (ECG)<\/td>\n<\/tr>\n<tr>\n<td>Effective Resolution<\/td>\n<td>15.5 bits<\/td>\n<\/tr>\n<tr>\n<td>Input Noise<\/td>\n<td>5 uVp-p<\/td>\n<\/tr>\n<tr>\n<td>CMRRR<\/td>\n<td>>100 dB<\/td>\n<\/tr>\n<tr>\n<td>Input Impedance<\/td>\n<td>>500 MOhm<\/td>\n<\/tr>\n<tr>\n<td>DC Offset Range<\/td>\n<td>+\/-650 mV<\/td>\n<\/tr>\n<tr>\n<td>AC Dynamic Range<\/td>\n<td>65 mVp-p<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629<\/td>\n<td>85 uW at 1.1V<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u064a\u0627\u0631 \u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>0.5 uA (typ)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0648\u0627\u062c\u0647\u0629<\/td>\n<td>SPI (up to 20 MHz)<\/td>\n<\/tr>\n<tr>\n<td>FIFO Depth<\/td>\n<td>32 words<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u0632\u0645\u0629<\/td>\n<td>30-bump WLP (2.7 x 2.9 mm)<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>0C to +70C (Commercial)<\/td>\n<\/tr>\n<\/table>\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a<\/h2>\n<ul>\n<li>Clinical-grade ECG AFE with 15.5-bit resolution<\/li>\n<li>Built-in R-R heart rate detection with interrupt output<\/li>\n<li>Ultra-low 85uW power consumption for wearable applications<\/li>\n<li>High CMRR >100dB with fully differential input<\/li>\n<li>High input impedance >500MOhm for dry electrode compatibility<\/li>\n<li>Leads-on detection for automatic MCU wake-up<\/li>\n<li>32-word FIFO for efficient data batching<\/li>\n<\/ul>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Wearable ECG chest strap monitors<\/li>\n<li>Single-lead wireless patches for arrhythmia detection<\/li>\n<li>Fitness heart rate monitoring bands<\/li>\n<li>Bio-authentication ECG-on-demand<\/li>\n<li>Hospital-grade ambulatory ECG monitors<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Product Overview The MAX30003CWV+T is an ultra-low power, single-channel integrated biopotential analog front-end (AFE) from Analog Devices (formerly Maxim Integrated), designed for ECG (electrocardiogram) and R-to-R heart rate detection in wearable applications. It features 15.5-bit effective resolution with 5uVp-p noise, built-in R-R detection algorithm, and operates on just 85uW at 1.1V. The CWV package is [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13,43],"tags":[526],"chip_brand":[178],"class_list":["post-9380","post","type-post","status-publish","format-standard","hentry","category-integrated-circuits-ics","category-temperature-sensors","tag-max30003cwv-t","chip_brand-analog-devices"],"acf":{"brief_explanation":"Ultra-low power ECG AFE, 15.5-bit, R-R detection, 85uW, 30-bump WLP (2.7x2.9mm), wearable grade","date_code":"25+","package_case":"30-bump WLP (2.7 x 2.9 mm, 0.4mm pitch)","in_stock":9232,"datasheet":"https:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/MAX30003.pdf","price":"$6.79 @ 1ku","product_introduction":"The MAX30003CWV+T is an ultra-low power single-channel biopotential AFE from Analog Devices, designed for wearable ECG and heart rate monitoring. It achieves clinical-grade 15.5-bit effective resolution with just 5uVp-p input noise, while consuming only 85uW at 1.1V supply. The built-in R-R heart rate detector with configurable interrupts eliminates the need to run HR algorithms on the host MCU, significantly reducing system power. The 30-bump WLP package (2.7x2.9mm) is optimized for space-constrained wearable designs.","working_principle":"The MAX30003CWV+T operates as a fully integrated ECG analog front-end. The biopotential channel receives differential ECG signals at the ECGP and ECGN pins, which first pass through ESD protection and EMI filtering. The fast-settling input amplifier with high input impedance (>500MOhm) amplifies the microvolt-level ECG signal while rejecting common-mode interference (CMRR >100dB). A programmable gain amplifier (PGA) further conditions the signal before an anti-aliasing filter (AAF, -3dB at 600Hz). The signal then enters a high-resolution sigma-delta ADC with programmable decimation filter. The R-R detector algorithm runs on the digitized ECG waveform, identifying QRS complexes and outputting heart rate data via the INTB interrupt pin. The 32-word FIFO allows the host MCU to remain in deep sleep until enough data accumulates, reducing overall system power consumption. DC lead-off detection uses a 0.7uA current source to monitor electrode connectivity.","pin_description":"<table>\n<tr><th>Pin<\/th><th>Name<\/th><th>Type<\/th><th>Function<\/th><\/tr>\n<tr><td>A1<\/td><td>ECGP<\/td><td>Analog Input<\/td><td>ECG positive differential input<\/td><\/tr>\n<tr><td>B1<\/td><td>ECGN<\/td><td>Analog Input<\/td><td>ECG negative differential input<\/td><\/tr>\n<tr><td>C2<\/td><td>VCM<\/td><td>Analog Output<\/td><td>Common-mode voltage output for right-leg drive<\/td><\/tr>\n<tr><td>D3<\/td><td>CSB<\/td><td>Digital Input<\/td><td>SPI chip select (active low)<\/td><\/tr>\n<tr><td>E3<\/td><td>SCLK<\/td><td>Digital Input<\/td><td>SPI clock input<\/td><\/tr>\n<tr><td>D4<\/td><td>SDI<\/td><td>Digital Input<\/td><td>SPI data input (MOSI)<\/td><\/tr>\n<tr><td>E4<\/td><td>SDO<\/td><td>Digital Output<\/td><td>SPI data output (MISO)<\/td><\/tr>\n<tr><td>C5<\/td><td>INTB<\/td><td>Digital Output<\/td><td>Interrupt output (active low), R-R detect \/ FIFO<\/td><\/tr>\n<tr><td>B5<\/td><td>INT2B<\/td><td>Digital Output<\/td><td>Second interrupt output<\/td><\/tr>\n<tr><td>A3\/A4<\/td><td>AVDD, DVDD<\/td><td>Power<\/td><td>Analog 1.1V, Digital 1.8V supply<\/td><\/tr>\n<\/table>","application_scenarios":"<table>\n<tr><th>Application<\/th><th>Circuit Role<\/th><th>Key Requirement<\/th><\/tr>\n<tr><td>Wearable ECG Patch<\/td><td>Single-lead ECG AFE<\/td><td>85uW, 15.5-bit, R-R detect, WLP<\/td><\/tr>\n<tr><td>Chest Strap HR Monitor<\/td><td>Heart rate detection only<\/td><td>R-R detect interrupt, 0.5uA standby<\/td><\/tr>\n<tr><td>Holter Monitor<\/td><td>Ambulatory ECG recording<\/td><td>15.5-bit, 32-word FIFO, clinical grade<\/td><\/tr>\n<tr><td>Smartwatch ECG<\/td><td>On-demand ECG measurement<\/td><td>WLP package, dry electrode support<\/td><\/tr>\n<tr><td>Medical IoT<\/td><td>Remote patient monitoring<\/td><td>Low power, SPI interface, FIFO batching<\/td><\/tr>\n<\/table>","alternative_models":"<table>\n<tr><th>Model<\/th><th>Manufacturer<\/th><th>Key Difference<\/th><\/tr>\n<tr><td>MAX30001CTI+<\/td><td>Analog Devices<\/td><td>Multi-channel version (ECG+BioZ)<\/td><\/tr>\n<tr><td>MAX30003CTI+<\/td><td>Analog Devices<\/td><td>Same AFE, 28-pin TQFN package<\/td><\/tr>\n<tr><td>AFE5404<\/td><td>Texas Instruments<\/td><td>4-channel ECG AFE, higher power<\/td><\/tr>\n<tr><td>ADS1292R<\/td><td>Texas Instruments<\/td><td>2-channel ECG\/Respiration AFE, 24-bit<\/td><\/tr>\n<tr><td>AD8233ACBZ<\/td><td>Analog Devices<\/td><td>Single-lead ECG analog front-end, lower cost<\/td><\/tr>\n<\/table>"},"_links":{"self":[{"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/posts\/9380","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/comments?post=9380"}],"version-history":[{"count":1,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/posts\/9380\/revisions"}],"predecessor-version":[{"id":9430,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/posts\/9380\/revisions\/9430"}],"wp:attachment":[{"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/media?parent=9380"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/categories?post=9380"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/tags?post=9380"},{"taxonomy":"chip_brand","embeddable":true,"href":"https:\/\/materialparts.com\/ar\/wp-json\/wp\/v2\/chip_brand?post=9380"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}